Choroid segmentation in OCT B-scans
Binary segmentation models for the choroid in OCT B-scans: the region between Bruch's membrane and the choroid-sclera interface. They are the first stage of the OcularRigidity pipeline: choroid segmentation, then video registration, then pulsation analysis.
Each version is on its own branch. Always load with an explicit revision.
Without one you get the weights of main, which is the first, legacy model
(described below), not the current one.
| Revision | Model | Training data | Status |
|---|---|---|---|
version-3.0.0 | UPerNet, ConvNeXt-Tiny encoder | Annotated in-house set (Zeiss PLEX Elite, Heidelberg Spectralis) + OIMHS | Current. Full model card on its branch |
version-2.0.0 | SegFormer, MiT-B2 encoder | Superseded | |
main | U-Net, SE-ResNet50 encoder | OIMHS only | Legacy, kept for reproducibility |
from ocularrigidity.segmentation.trainer.pl_module import ChoroidSegmentationModule
model = ChoroidSegmentationModule.from_pretrained(
"ClementP/ChoroidSegmentationModule", revision="version-3.0.0"
).eval()
The registration model
ClementP/OCTVideoRegistration
reads the encoder features of version-3.0.0, so the two must be used together.
The model on main (legacy)
The first model of the project, uploaded in May 2026.
| Architecture | U-Net, SE-ResNet50 encoder (ImageNet init), from segmentation_models_pytorch |
| Input | 1 channel (grayscale B-scan), normalised as (x / 255 - 0.5) / 0.5 |
| Output | 1 channel of logits; choroid = logit > 0 |
| Training data | OIMHS only (Heidelberg Spectralis, macular-hole patients, choroid label), 80 / 20 split by patient (seed 42) |
| Input scale in training | OIMHS B-scans resized from 496 × 512 to 1024 × 1024, meant to approximate the PLEX Elite pixel size |
| Augmentation | Horizontal flip, scale 0.8–1.2 (lateral) and 0.75–1.25 (axial), rotation ±5°, Gaussian noise, brightness and contrast |
| Loss | Dice + cross-entropy, plus thickness-smoothness (0.05) and gap-detection (0.05) terms |
| Optimiser | AdamW, learning rate 1e-4, weight decay 1e-5, batch size 16, early stopping on validation Dice |
| Validation Dice | 0.986, on the OIMHS validation patients only |
It never saw a PLEX Elite image in training, and it was evaluated on OIMHS only. Its Dice cannot be compared with the scores of later versions, which are measured on a mixed in-house + OIMHS split.
Research use only. This is not a medical device.
Citation
If you use these models, please cite the OcularRigidity work (reference to come) and the OIMHS dataset:
Ye, X., He, S., Zhong, X. et al. OIMHS: An Optical Coherence Tomography Image Dataset Based on Macular Hole Manual Segmentation. Sci Data 10, 769 (2023). https://doi.org/10.1038/s41597-023-02675-1